VANTAGE 575 CUMMINS
OPERATOR’S MANUAL
IM10044
March, 2010
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation ...
and thoughtful operation on your
part. DO NOT INSTALL, OPER-
ATE OR REPAIR THIS EQUIP-
MENT WITHOUT READING
THIS MANUAL AND THE SAFE-
TY PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
For use with machine having Code Number:
11686
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © Lincoln Global Inc.
®
RETURN TO MAIN MENU
Vedere la pagina 0
1 2 3 4 5 6 ... 52 53

Sommario

Pagina 1 - VANTAGE 575 CUMMINS

VANTAGE 575 CUMMINSOPERATOR’S MANUALIM10044March, 2010Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety i

Pagina 2 - MAGNETIC FIELDS

ixixTABLE OF CONTENTSAccessories...Section cOptio

Pagina 3 - ARC RAYS can burn

VANTAGE® 575 CUMMINS A-1INSTALLATION A-1TECHNICAL SPECIFICATIONS - VANTAGE® 575 CUMMINS (K2170-2) Make/Model Description Speed (RPM) Displacement

Pagina 4

A-2INSTALLATION VANTAGE® 575 CUMMINS A-2SAFETY PRECAUTIONSOnly qualified personnel should install, use, or service this equipment.Do not attempt to

Pagina 5 - REDRESSEUR

A-3INSTALLATION VANTAGE® 575 CUMMINS A-3LIFTINGThe VANTAGE® 575 CUMMINS lift bale should beused to lift the machine. The VANTAGE® 575 CUM-MINS is sh

Pagina 6 - L10093 3-1-96H

ENGINE COOLANTHOT COOLANT can burn skin.•Do not remove cap if radiator is hot.------------------------------------------------------------------------

Pagina 7

A-5INSTALLATION VANTAGE® 575 CUMMINS A-5The VANTAGE® 575 CUMMINS is shipped with the nega-tive battery cable disconnected. Before you operate themac

Pagina 8 - Thank You

A-6INSTALLATION VANTAGE® 575 CUMMINS A-6REMOTE CONTROLThe VANTAGE® 575 CUMMINS is equipped with a 6-pin and a 14-pin connector. The 6-pin connector

Pagina 9

A-7INSTALLATION VANTAGE® 575 CUMMINS A-7CONNECTION OF LINCOLN ELEC-TRIC WIRE FEEDERSShut off welder before making any electrical con-nections.------

Pagina 10 - TABLE OF CONTENTS

A-8INSTALLATION VANTAGE® 575 CUMMINS A-8CONNECTION OF AN NA-3 AUTOMATICWELDING SYSTEM TO THE VANTAGE®575 CUMMINSFor connection diagrams and instruct

Pagina 11 - INSTALLATION

B-1OPERATIONVANTAGE® 575 CUMMINSB-1SAFETY PRECAUTIONSRead and understand this entire section beforeoperating your VANTAGE® 575 CUMMINS.Do not attempt

Pagina 12

iSAFETYiFOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be

Pagina 13

B-2OPERATIONB-2ENGINE CONTROLS (Items 1 through 9)1. RUN STOP SWITCHToggling the switch to the RUN position energizesthe fuel so

Pagina 14

B-3OPERATIONB-37. OIL PRESSURE GAUGEThe gauge displays the engine oil pressure whenthe engine is running.8. ENGINE PROTECTIONThe yellow engine protect

Pagina 15

B-4OPERATIONB-413. WELD MODE SELECTOR SWITCH:(Provides 3 selectable welding modes)CV-WIRECC-STICKTOUCH START TIG14. ARC CONTROL:The ARC CONTROL WIRE/S

Pagina 16

B-5OPERATIONB-523. 415 VAC RECEPTACLEThis is a 415VAC receptacle that provides auxil-iary power. This receptacle has 32 amp ratingand IP66 rated. Refe

Pagina 17

B-6OPERATIONB-6WHAT ARE VRD AND ROCV DEVICES?VRD’s are gaining popularity as a “must have” safetyaccessory especially where welding applications arebe

Pagina 18

B-7OPERATIONB-7Unlike other VRD’s Lincoln uses micro processor con-trol to monitor and establish the arc without the stick-ing and shorting of the ele

Pagina 19 - OPERATION

The VANTAGE® 575 CUMMINSis equipped with therequired R.F. bypass circuitry for the connection ofhigh frequency generating equipment. The VANTAGE® 575

Pagina 20

ARC GOUGINGFor optimal performance when arc gouging, set theVANTAGE® 575 CUMMINS“WELD MODE” switch tothe “CC - STICK” position, and the “ARC CONTROL”t

Pagina 21

PARALLELINGWhen paralleling machines in order to combine theiroutputs, all units must be operated in the CC-STICKmode only at the same output settings

Pagina 22

K2354-1 AIR DRYER KIT - Minimizes water contentin supply air. Avoids cold weather air hose ice up. K2356-1 CONTROL PANEL COVER KIT - Clearplexiglass c

Pagina 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Pagina 24

D-1MAINTENANCED-1VANTAGE® 575 CUMMINS SAFETY PRECAUTIONS• Have qualified personnel do all maintenanceand troubleshooting work.• Turn the engine off be

Pagina 25

D-2MAINTENANCED-2VANTAGE® 575 CUMMINSUnfasten or unlatch theservice cover. Becausethe filter fits tightly over theoutlet tube to create the critical s

Pagina 26

D-3MAINTENANCED-3FUEL FILTERSWhen working on the fuel system:• Keep naked lights away, do not smoke !• Do not spill fuel !----------------------------

Pagina 27

D-4MAINTENANCED-4CHARGING THE BATTERYWhen you charge, jump, replace, or otherwise connectbattery cables to the battery, be sure the polarity iscorrect

Pagina 28

E-1TROUBLESHOOTINGE-1VANTAGE® 575 CUMMINS If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safel

Pagina 29 - ACCESSORIES

E-2TROUBLESHOOTINGE-2VANTAGE® 575 CUMMINS Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the tes

Pagina 30 - MAINTENANCE

E-3TROUBLESHOOTINGE-3Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or are u

Pagina 31 - Service Instructions

E-4TROUBLESHOOTINGE-4VANTAGE® 575 CUMMINS Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the tes

Pagina 32

F-1WIRING DIAGRAMF-1VANTAGE® 575 CUMMINS NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.

Pagina 33

F-2DIAGRAMSF-2VANTAGE® 575 CUMMINS

Pagina 34 - TROUBLESHOOTING

iiiSAFETYiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.

Pagina 35

F-3DIAGRAMSF-3VANTAGE® 575 CUMMINS GND757677GREENK291 OR K40475INPUT CABLE76N.E.77K775 OPTIONALREMOTE CONTROLDAMAGED. THE ENGINE GOVERNOR SETTING IS P

Pagina 36

F-4DIAGRAMSF-4VANTAGE® 575 CUMMINS

Pagina 37

F-5DIAGRAMSF-5VANTAGE® 575 CUMMINS

Pagina 38 - WIRING DIAGRAM

F-6DIAGRAMSF-6VANTAGE® 575 CUMMINS CAUTION : N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

Pagina 39 -

F-7DIAGRAMSF-7VANTAGE® 575 CUMMINS

Pagina 40 - DIAGRAMS

F-8DIAGRAMSF-8VANTAGE® 575 CUMMINS

Pagina 41

F-9DIAGRAMSF-9VANTAGE® 575 CUMMINS

Pagina 42

F-10DIAGRAMSF-10VANTAGE® 575 CUMMINS

Pagina 43

F-11DIAGRAMSF-11VANTAGE® 575 CUMMINS 29/03

Pagina 44

F-12DIAGRAMSF-12VANTAGE® 575 CUMMINS

Pagina 45

ivSAFETYivMar. ‘93PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques q

Pagina 46

F-13DIMENSION PRINTF-13VANTAGE® 575 CUMMINS ****BOTTOM VVIEW OOF WWELDER BBASE.N.A. . CCENTETER OOF GRGRAVITYTY WWITH OOIL I IN EENGINE, EEMPTY FFUEL

Pagina 47

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Pagina 48

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Pagina 49

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Pagina 50 - DIMENSION PRINT

vSAFETYvVANTAGE® 575 CUMMINSElectromagnetic Compatibility (EMC)ConformanceProducts displaying the CE mark are in conformity with European Community Co

Pagina 51

viSAFETYviVANTAGE® 575 CUMMINSElectromagnetic Compatibility (EMC)The size of the surrounding area to be considered will depend on the structure of the

Pagina 52

viiviiThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as

Pagina 53

viiiviii TABLE OF CONTENTSPageInstallation...........................

Commenti su questo manuale

Nessun commento